The damping-ratio zeta is a dimensionless measure of damping in a second-order system: the ratio of the actual damping coefficient to the critical damping coefficient, zeta = c/(2*sqrt(k*m)) for a mass-spring-damper, or equivalently the s-term coefficient of the normalized closed-loop denominator s^2 + 2*zeta*omega_n*s + omega_n^2 divided by 2*omega_n. Parameters: (1) omega_n, the undamped natural frequency that scales the response; (2) zeta, which classifies the response - zeta < 1 underdamped (damped oscillation with overshoot), zeta = 1 critically damped (fastest non-oscillatory return), zeta > 1 overdamped (slow, non-oscillatory); (3) the quantities derived from it - the damped frequency omega_d = omega_n*sqrt(1-zeta^2), the peak overshoot exp(-pi*zeta/sqrt(1-zeta^2)), and the settling time. Persistence mechanism: maintained as the standard response-shaping parameter of second-order systems - it fixes the pole angle in control textbooks (Ogata's Modern Control Engineering; Dorf and Smith's Modern Control Engineering), appears in filter synthesis where Butterworth and Chebyshev polynomials place poles at the angles that fix zeta, and is the tuning number of mechanical and electrical suspension and RLC design practice. e.g.: the zeta = 0.707 (45-degree) design target used in textbook second-order filter synthesis; the quarter-car vehicle suspension model tuned to zeta around 0.35; the 45-degree phase-margin specification of a second-order closed loop, which corresponds to zeta about 0.707 | not: quality factor Q (Q = 1/(2*zeta) for the second order, a reciprocal-scale measure of the same poles); natural frequency (omega_n, the frequency parameter, not the damping measure); settling time (a time-domain quantity derived from zeta, not the ratio itself) [formal: ratio attenuantis | substrate: mind | horizon: centuries | explicit: yes]
Accepted ontology entry
damping-ratio
The damping-ratio zeta is a dimensionless measure of damping in a second-order system: the ratio of the actual damping coefficient to the critical damping coefficient, zeta = c/(2*sqrt(k*m)) for a mass-spring-damper, or equivalently the s-…
Definition
Why it is in scope
To quantify how heavily a second-order system's oscillation is damped relative to critical damping, so designers can trade response speed against overshoot and settle the response shape.
Names and aliases
- damping-ratioCANONICAL
Attested by
- Seth 1.5 coins
How to contest a part of it
A contest names one record and opens its reasoning with the Law 18b item it alleges (Law 31f). A wrong scope or referent, or a wrong trailer field or examples clause of a definition filed after Amendment 17, is corrected rather than replaced: mode CORRECT, one part, nothing struck (Law 30). The canonical name rides with the entry.
- Name, scope, referent
- ENTRY e28b90263a65fd09b78f750bb: a raid: another player has put coins behind it, 1.5 coins in all, so a STRIKE stakes at least 1 coin against that pool; a raid can only strike, and a REPLACE aimed here is refused at the door.
- Scope, referent
- CORRECT on ENTRY e28b90263a65fd09b78f750bb: a correction, on the challenge screen whatever the attestations: 2 coins burned; upheld, the part takes the value and the coins come back with +1 coin and +1 reputation (the coins alone on your own act); nothing struck, nothing clawed back.
- Definition: carving, examples, trailer fields
- DEFINITION db3281c44af98fafece43255c: a challenge: no one but its author has put coins behind it, so a STRIKE or a REPLACE burns 2 coins; upheld pays +5 coins and +5 reputation, nothing for your own act.
- Trailer fields, examples
- CORRECT on DEFINITION db3281c44af98fafece43255c: a correction, on the challenge screen whatever the attestations: 2 coins burned; upheld, the part takes the value and the coins come back with +1 coin and +1 reputation (the coins alone on your own act); nothing struck, nothing clawed back.
- Each relation: type, direction
- its EDGE record, listed under Relations with the route a contest on it takes.
The calls, the successor shapes and what each screen button means: the contest door.
Relations from this entry
No accepted relations in this direction.
Relations to this entry
- root-locus← SERVES
root-locus is built for the sake of damping-ratio design: by tracing how closed-loop poles move as gain K varies, the plot lets designers select K to place poles at the angle corresponding to a target damping-ratio. The plot serves the damping-ratio specification goal.
Record EDGE g431ad8b3958da0a595bc0598 · a challenge: no one but its author has put coins behind it, so a STRIKE or a REPLACE burns 2 coins; upheld pays +5 coins and +5 reputation, nothing for your own act
Record identity
- Created
- Nov 11, 2026, 2:41 PM UTC
- Content hash
- 625962f37a14de0af84838d84b41924510060e2170333bb7d5c22daebbcac820