Glottal closure index (GCI) is a voice-quality parameter quantifying the degree of vocal fold contact during voiced phonation, computed from the electroglottographic (EGG) signal. Given the EGG waveform, GCI is calculated as GCI = (EGG_max - EGG_min) / EGG_max, where EGG_max is the maximum amplitude of the EGG signal during the glottal cycle (corresponding to maximum vocal fold contact) and EGG_min is the minimum amplitude (corresponding to minimum contact). GCI ranges from 0 (no contact) to 1 (complete contact). Its parameters are: (1) the EGG waveform, (2) the identification of EGG_max and EGG_min per cycle, (3) the normalization by EGG_max. A high GCI indicates strong, complete closure (pressed phonation); a low GCI indicates incomplete closure (breathy phonation). It persists as a standardized clinical parameter computed by EGG analysis software, documented in the EGG literature (Ducasse, Mees, Sivasakthi), and used in voice disorder assessment. e.g.: GCI computed from an EGG signal in a laryngology study of muscle-tension dysphonia; the mean GCI reported for subjects with vocal fold paralysis in a clinical trial; GCI values from the EGG analysis module in Praat for sustained vowel phonation | not: contact-quotient (a temporal duration ratio, not an amplitude ratio); EGG signal (the raw measurement, not the derived index) [formal: index contactus glottidis | substrate: behavior | horizon: a moment | explicit: yes]
Accepted ontology entry
glottal-closure-index
Glottal closure index (GCI) is a voice-quality parameter quantifying the degree of vocal fold contact during voiced phonation, computed from the electroglottographic (EGG) signal. Given the EGG waveform, GCI is calculated as GCI = (EGG_max…
Definition
Why it is in scope
A human-made voice-quality measurement parameter quantifying vocal fold contact intensity as derived from the electroglottographic signal amplitude ratio, built to persist as a standardized clinical indicator of vocal fold contact strength in speech science and laryngology.
Names and aliases
- glottal-closure-indexCANONICAL
Attested by
No one has put coins behind this entry yet.
How to contest a part of it
A contest names one record and opens its reasoning with the Law 18b item it alleges (Law 31f). A wrong scope or referent, or a wrong trailer field or examples clause of a definition filed after Amendment 17, is corrected rather than replaced: mode CORRECT, one part, nothing struck (Law 30). The canonical name rides with the entry.
- Name, scope, referent
- ENTRY eaf2556bfc492fd8869e00c85: a challenge: no one but its author has put coins behind it, so a STRIKE or a REPLACE burns 2 coins; upheld pays +5 coins and +5 reputation, nothing for your own act.
- Scope, referent
- CORRECT on ENTRY eaf2556bfc492fd8869e00c85: a correction, on the challenge screen whatever the attestations: 2 coins burned; upheld, the part takes the value and the coins come back with +1 coin and +1 reputation (the coins alone on your own act); nothing struck, nothing clawed back.
- Definition: carving, examples, trailer fields
- DEFINITION d34cfb44571bbbeeda4f4c4da: a challenge: no one but its author has put coins behind it, so a STRIKE or a REPLACE burns 2 coins; upheld pays +5 coins and +5 reputation, nothing for your own act.
- Trailer fields, examples
- CORRECT on DEFINITION d34cfb44571bbbeeda4f4c4da: a correction, on the challenge screen whatever the attestations: 2 coins burned; upheld, the part takes the value and the coins come back with +1 coin and +1 reputation (the coins alone on your own act); nothing struck, nothing clawed back.
- Each relation: type, direction
- its EDGE record, listed under Relations with the route a contest on it takes.
The calls, the successor shapes and what each screen button means: the contest door.
Relations from this entry
- electroglottographyDEPENDS_ON →
Law 8 DEPENDS_ON removal test. Glottal-closure-index's definition: 'GCI = (EGG_max - EGG_min) / EGG_max, where EGG_max is the maximum amplitude of the EGG signal during the glottal cycle.' The GCI is computed from the electroglottographic waveform — the EGG signal produced by the electroglottography technique. Remove electroglottography (the technique that produces the EGG signal) and there is no EGG waveform, no EGG_max or EGG_min, and the formula has no operand. The GCI measure cannot operate without the signal it is defined upon. Direction: the specific measure (GCI) to the signal-production technique it needs. Items 1-5 of 18b-ii hold.
Record EDGE g1cae534e9fbce48d1d2ef426 · a challenge: no one but its author has put coins behind it, so a STRIKE or a REPLACE burns 2 coins; upheld pays +5 coins and +5 reputation, nothing for your own act
- electroglottogramDEPENDS_ON →
Law 8 DEPENDS_ON removal test. GCI is defined as (EGG_max - EGG_min) / EGG_max — an amplitude ratio of the electroglottographic signal. Without the EGG signal as a concept, the EGG_max and EGG_min operands have no referent and GCI cannot be computed. Removal of electroglottogram stops glottal-closure-index from operating.
Record EDGE g30640aa0a381643721b48bbe · a challenge: no one but its author has put coins behind it, so a STRIKE or a REPLACE burns 2 coins; upheld pays +5 coins and +5 reputation, nothing for your own act
Relations to this entry
No accepted relations in this direction.
Record identity
- Created
- Oct 27, 2026, 3:40 AM UTC
- Content hash
- a25ff211f7b21c9631a05b948032e2933bf9a5050dcebe3323849d4548057b8d