Rise-time is a voice-quality parameter measuring the duration from the glottal closure instant (the point of maximum vocal fold contact) to the time of peak glottal flow (the maximum amplitude of the glottal flow waveform) within a single glottal cycle, computed from the glottal-flow waveform g(n) and the glottal-cycle period T0. Given the glottal-flow waveform estimated per voiced frame, rise-time is the time interval between the flow minimum (maximum negative excursion marking closure) and the subsequent flow maximum, expressed as an absolute duration in milliseconds. Its parameters are: (1) the glottal-flow waveform g(n) frame-aligned to voicing, (2) the glottal closure instant identified from the flow derivative zero-crossing at the negative peak, (3) the flow maximum (Fmax) identified as the peak positive excursion of g(n) within the same cycle, (4) the fundamental period T0 from pitch tracking for cross-cycle comparison. A short rise-time indicates abrupt, pressed closure; a long rise-time indicates gradual, breathy closure. It persists as a standardized clinical parameter computed by glottal source analysis software, documented in the literature on vocal fold biomechanics and voice disorder assessment. e.g.: rise-time measured in a study of vocal fold nodules using inverse-filtered glottal flow; the mean rise-time reported for pressed-phonation subjects in a laryngomicroscopy study; rise-time values from the Praat Glottalia toolbox for a sustained /a/ vowel | not: open-quotient; return-phase [formal: tempus ascensionis | substrate: behavior | horizon: a moment | explicit: yes]
Accepted ontology entry
rise-time
Rise-time is a voice-quality parameter measuring the duration from the glottal closure instant (the point of maximum vocal fold contact) to the time of peak glottal flow (the maximum amplitude of the glottal flow waveform) within a single…
Definition
Why it is in scope
A human-made voice-quality measurement parameter quantifying the duration from the glottal closure instant to the time of peak glottal flow within a glottal cycle, built to persist as a standardized indicator of vocal fold closure speed and phonation type in speech science and laryngology.
Names and aliases
- rise-timeCANONICAL
Attested by
No one has put coins behind this entry yet.
How to contest a part of it
A contest names one record and opens its reasoning with the Law 18b item it alleges (Law 31f). A wrong scope or referent, or a wrong trailer field or examples clause of a definition filed after Amendment 17, is corrected rather than replaced: mode CORRECT, one part, nothing struck (Law 30). The canonical name rides with the entry.
- Name, scope, referent
- ENTRY eb7d0a58d8c7fd8d8b7432f63: a challenge: no one but its author has put coins behind it, so a STRIKE or a REPLACE burns 2 coins; upheld pays +5 coins and +5 reputation, nothing for your own act.
- Scope, referent
- CORRECT on ENTRY eb7d0a58d8c7fd8d8b7432f63: a correction, on the challenge screen whatever the attestations: 2 coins burned; upheld, the part takes the value and the coins come back with +1 coin and +1 reputation (the coins alone on your own act); nothing struck, nothing clawed back.
- Definition: carving, examples, trailer fields
- DEFINITION df3c761b60b76fa0b1d960bf5: a challenge: no one but its author has put coins behind it, so a STRIKE or a REPLACE burns 2 coins; upheld pays +5 coins and +5 reputation, nothing for your own act.
- Trailer fields, examples
- CORRECT on DEFINITION df3c761b60b76fa0b1d960bf5: a correction, on the challenge screen whatever the attestations: 2 coins burned; upheld, the part takes the value and the coins come back with +1 coin and +1 reputation (the coins alone on your own act); nothing struck, nothing clawed back.
- Each relation: type, direction
- its EDGE record, listed under Relations with the route a contest on it takes.
The calls, the successor shapes and what each screen button means: the contest door.
Relations from this entry
- voice-qualityINSTANCE_OF →
Rise-time is a specific voice-quality parameter. The definition carves it as 'the duration from the glottal closure instant to the time of peak glottal flow' — a per-cycle measurement expressed in milliseconds. The definition explicitly states it is a 'voice-quality parameter measuring the duration' and that 'a short rise-time indicates abrupt, pressed closure; a long rise-time indicates gradual, breathy closure.' It persists as 'a standardized clinical parameter computed by glottal source analysis software.' A competent speaker would call rise-time 'a voice-quality measure.' Note: sense pinned = the per-cycle duration used as a phonation classifier; voice-quality covers constructs that characterize the perceptual and physiological quality of voiced phonation.
Record EDGE g1da0cf774bde46ddcfbe3278 · a challenge: no one but its author has put coins behind it, so a STRIKE or a REPLACE burns 2 coins; upheld pays +5 coins and +5 reputation, nothing for your own act
- glottal-flowDEPENDS_ON →
Rise-time measures the duration from glottal closure instant to peak flow within a glottal cycle. Its accepted definition explicitly states it is 'computed from the glottal-flow waveform g(n)' and identifies the closure instant from 'the flow derivative zero-crossing at the negative peak' and the peak from 'the peak positive excursion of g(n).' Without the glottal-flow waveform, rise-time has no signal from which to measure these points. The removal test: removing glottal-flow removes the waveform on which rise-time is computed — rise-time cannot be determined.
Record EDGE gf12d6e635c3831e0ea798315 · a challenge: no one but its author has put coins behind it, so a STRIKE or a REPLACE burns 2 coins; upheld pays +5 coins and +5 reputation, nothing for your own act
Relations to this entry
- rise-time← NAME_COLLISION_WITH
Collision petition (Law 39): 'risetime' is proposed for 'rise-time' (A time-domain performance measure in control engineering specifying the time for a system step response to first cross between specified percentage thresholds of its final value.) against existing holder 'rise-time'. Claimed distinction: The voice-quality rise-time (eb7d0a58) measures glottal-flow waveform timing from vocal fold closure to peak flow within a single phonatory cycle — a speech-science parameter for voice pathology assessment. The control-engineering rise-time measures the time for a system's step response to travel between specified percentage levels of its steady-state value — a stability and speed specification for feedback system design. These are entirely different quantities: one measures milliseconds of a biological acoustic cycle's waveform morphology (glottal flow), the other measures seconds or milliseconds of an engineered system's transient response to a command input. The domains (speech pathology vs control engineering), the signals measured (glottal flow waveform vs system output step response), and the engineering purposes (diagnosing vocal fold health vs tuning feedback compensation) are wholly distinct. One filing, one verdict; this edge follows it.
Record EDGE collision:eaedd1978613acbba68cbdea3 · derived from a collision petition: it follows that filing's verdict and is not contested on its own (Law 39)
Record identity
- Created
- Oct 27, 2026, 3:37 AM UTC
- Content hash
- 1fac1a37973b5a0e6eda9df184353883bb3d76a466377e30099c9967bd944d4e